The World’s first in-situ borehole gas monitor!

GasClam can be used below ground for up to three months to measure a variety of gases, with temperature, barometric and borehole pressure giving a true long term profile for the first time! It’s truly the definitive method of measurement for most below ground applications.

Key features:

  Easy installation in a secure 50mm or 2 inch borehole
  Three months continuous un-manned data collection
  Methane (CH4), oxygen (O2) and carbon dioxide (C02)
  Temperature, borehole and atmospheric pressure
  Optional CO or VOC plus water depth
  Runs on two standard D-cell batteries
  Explosion Proof
  Programmable borehole venting

TRADITIONAL METHODS

Using portable gas detection instruments to spot check boreholes from time to time is fraught with potential issues. Considerable published material exists that question whether the traditional method of collecting gas-data from boreholes is at all adequate.

The use of the numerous guidance notes from the legislators and enforcers would seem to indicate they too think the current methods are flawed. To evaluate boreholes effectively detailed and frequent measurements are required, particularly when events occur e.g. such as when the barometric pressure falls. Data collected on in periodic spot check basis does not give a complete picture so decisions are made reliant on historic set points rather than real trend information on the borehole being monitored.

Current issues:

1. Spot check data only available.
2. Major gas events are often missed.
3. Lack of real data leads to misleading conclusions.
4. Frequent expensive site visits to take only spot readings.
5. Independent borehole profiles are just not available.

All these uncertainties led Salamander to develop the unique and patent pending GasClam which is designed as the definitive solution.

BENEFITS

  Reduction of unnecessary site visits
  Complete data for a full site assessment
  Demonstrates full due diligence
  Meets all legislative needs
  All relevant data including barometric pressure logged simultaneously
  Data can be downloaded on site for quick analysis
  All events are captured with a time and date stamp for further analysis
  Removal of any uncertainty in gas monitoring regime
  Assists with design of gas protection measures
  Validates operation for Biogas production
  Also can monitor greenhouse-gas emissions
  A post site development monitor for extra safety
  Optional carbon monoxide (CO) or volatile organic compound (VOC) sensor for specific applications
  Optional water depth sensor where ground water influences results
  Control vent boreholes to measure concentration build up times
  Optional telemetry system for real-time monitoring on critical sites

TYPICAL APPLICATIONS

On Landfill Sites

  Perimeter monitoring using existing boreholes
  Accurate real-time measurement of Green House gases
  Discharge of licence when used as a post-closure monitor
  Spontaneous combustion detection
  Long term monitoring

On Brownfield sites and Disused Coal Mines

  Site investigation
  Validation of any remediation untaken or needed
  After site development validation and monitoring
  General due diligence

For Petroleum/ Solvent Storage and Filling Stations

  Leak site investigation
  Perimeter monitoring
  Early validation of effective bunding or need to repair
  Long term spillage monitoring
  Compliance to the Regulations

On Refineries

  An integral part of long term monitoring procedures
  An independent check on other monitoring techniques
  Incident use after spillage
  Demonstration of due diligence
  C02 Sequestration monitoring

Below Ground Carbon Capture and Storage

  Validation of storage sites: peat bogs, etc
  Long term site surveys for suitability
  Validation of compliance



Data Sheet
Manual

THE GASCLAM SOLUTION FOR:-

LANDFILL - Gas generation and migration are subject to operational control on landfill sites. GasClam data can be used as the feedback to ensure control is effective particularly where Biogas is used and greenhousegas emission levels measured. Below ground fires as a result of spontaneous combustion can be monitored using the optional CO sensor fitted to the GasClam. An accurate assessment can be made of severity and the extent of the landfill effected this is essential for full risk assessment.

BROWNFIELD AND DISUSED COAL MINES - With GasClam, periods of continuous monitoring can be practically and economically incorporated into site Investigations. With full data available, boreholes can be profiled and the optimum monitoring programme ascertained. A time saving tool whilst reducing risks at the same time. Where sites show significant gas present these can be long term monitored to ensure the risks are fully understood before remedial actions are recommended.

PETROLEUM STORAGE AND FILLING STATIONS - Below ground storage of petroleum is currently the norm when associated with filling stations. As tanks age and connections corrode the repair of the inevitable leak represents a significant environmental hazard. Used in some well placed boreholes the GasClam with optional VOC sensor fitted can monitor sites to ensure leakage is kept to a minimum or even indicate where repair may be necessary. After repairs or clean-up the GasClam can be used to validate the result for the local authorities or regulatory bodies. Long-term deployment produces data that can be used for management of operations and can be incorporated into risk assessments for storage facilities.

This method of leak detection is sure and certain.

CARBON CAPTURE AND STORAGE - With carbon trading a reality, carbon offsetting and storage has become a major commercial enterprise. However, it is limited at present because of disagreements and difficulties in verification of longevity of storage. The GasClam with its ability to continuously measure and the potential to use this data to calculate gas fluxes – is likely to be indispensible during the growth of this new business area.

Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.


Back To Last Page

Autozeroing Mercury Instrument (AMI)

FirstCheck+ PID Multi-Gas Detector

GasCheck G (G1, G2 & G3)

GasCheck IS (3000 and 5000)

GasClam Borehole Gas Monitor

Mercury Vapour Indicator (MVI)

PhoCheck+ PID Detector

PhoCheck Tiger Handheld VOC Detector

Tiger Select Compound Monitor

Total VOC Detector

Want A Quotation?

Please fill out the following fields and we will e-mail you a quotation shortly.

Name:
Company:
Country:
E-Mail:
Telephone:
Product(s):
Quantity:
Other Details:
ISO 9001
More Information

CONTACT KEISON INTERNATIONAL LTD

Telephone: +44 (0)1245 600 560

Fax: +44 (0)1245 808 399

E-mail: info@keison.com

ISO 140001
More Information
We are open Monday to Friday, from 9.30 - 5.30 GMT.

© Copyright 2012 Keison International Ltd - All Rights Reserved.